62 TESTER
Tester does not power up when connected to the vehicle
battery via the cigarette lighter or battery adapter cable
MOST LIKELY CAUSE:
DC power cable not making good contact.
Vehicle cigarette lighter fuse is blown.
Fuse in DC power cable cigarette lighter plug is blown.
RECOMMENDATIONS:
Disconnect and reconnect the DC power cord. Verify that the power cord is connected
properly.
Replace vehicle cigarette lighter fuse.
Replace fuse in DC power cable cigarette lighter plug as follows:
1. Disconnect the DC power cable from the Tester.
2. A 3A fuse is built into the power plug on the DC power cable. Check and replace the
fuse as follows:
A. Remove the power plug cover and remove the fuse together with the spring. The
spring and power plug terminal can pop out so take care not to lose them.
B. Check the fuse and replace it if necessary.
C. Install the fuse and spring into the power plug.
D. Check that the power plug terminal is inside the power plug cover, then screw the
cover onto the power plug.
DC POWER CABLE PLUG
DC POWER
CABLE
FUSE
POWER PLUG TERMINAL
POWER PLUG COVER