54 TESTER
4. To remove the battery pack cover, grasp the battery pack with one hand and position a
screwdriver (flat blade) as shown in the figure below. Push the screwdriver blade
against the battery pack side wall and the battery cover. While pushing, twist the
screwdriver slightly until the cover pops loose from the locking tabs. Repeat for the
other side.
5. Remove the six NiCad batteries.
6. Install the new batteries with the positive (+) and negative (-) terminals oriented as
indicated on the inside of the battery pack.
7. Place the cover on the battery case so the tabs at the top of the cover are aligned with
the slots in the case, and the slots at the bottom of the cover are aligned with the tabs on
the case.
8. Press the arrows on the battery cover while pushing the cover toward the top of the
case. The cover should snap into place.
9. Slide the battery pack onto the Tester so the tab at the top fits into the slot on the Tester.
The battery pack should lock into place.
LITHIUM BATTERY
The lithium battery, located on the underside of the Tester behind the NiCad battery pack,
enables the Tester to retain setup information and data in its memory without being
connected to an external power source.
The lithium battery should last approximately two years before replacement is necessary.
The Tester displays the screen at left when the lithium battery is discharged (dead) or a
new battery has just been installed. This screen is also displayed if the plastic strips are not
removed before operating the Tester for the first time.
REMOVING THE BATTERY PACK COVER
NICAD
BATTERY PACK
TWIST THE
SCREWDRIVER
SLIGHTLY UNTIL THE
COVER POPS LOOSE
CAUTION
ATTENTION!
NiCad batteries are recyclable. Under various state and local
laws it may be illegal to dispose of NiCad batteries in the
municipal waste system. Check with local solid waste officials
in your area for recycling options or proper disposal methods.