SEKURE SX-3100LCD Manuel de l'opérateur Page 378

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 378
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 377
366 GAS ANALYZER
E. TECHNICAL SPECIFICATIONS
Dimensions 13" x 6.5" x 7.3"
Weight 12 lbs.
Power Requirements 12VDC @ 3A
Storage Temperature -29°C to 70°C (-20°F to 158°F)
Operating Temperature 2°C to 50°C (35°F to 122°F)
Warmup Time 15 minutes maximum
Relative Humidity 0-90% non-condensing
GAS RANGE RESOLUTION ACCURACY
HC 0–20,000 ppm 1 ppm 6 ppm greater than absolute or
5% of reading
CO 0–10% 0.01% 0.06% greater than absolute or
5% of reading
CO2 0–20% 0.1% 0.5% greater than absolute or
5% of reading
O2 0–25% 0.01% 0.01% greater than absolute or
5% of reading
NOx 0–4000 ppm 1 ppm 32 ppm at 0-1000 ppm
60 ppm at 1001-2000 ppm
120 ppm at 2001-4000 ppm
NOTE
Accuracy specifications are based on bottled, dry calibration
gas.
Vue de la page 377
1 2 ... 373 374 375 376 377 378

Commentaires sur ces manuels

Pas de commentaire