DIGIPLEXNE CONTROL PANEL 3
1 INTRODUCTION
DigiplexNE is a security and access control system with 8 on-board zone
inputs (16 with zone doubling) that is expandable to 96 zones via the 4-wire
combus. DigiplexNE features up to 999 users, 8 partitions, 32 doors, 32
schedules, 16 access levels, and can support up to 127 modules in any
combination.
DigiplexNE systems provide the highest level of protection for banks, high-
security military and government sites, luxurious residential homes and any
place where maximum security is essential. These systems are designed to
be easy to use, and the modular concept of these systems provides
installer’s with labour-saving features that make expanding, installing and
servicing these systems quick and convenient.
Expand the DigiplexNE system by adding plug-and-play expansion modules
anywhere and in any combination on the 4-wire combus. Modules are
connected to the combus at the most convenient location and then their zone
inputs are assigned to the desired zone and partition. Also, only a module’s
used inputs are assigned to zones in the system. Keyswitches, remote
controls and unused module inputs do not use up zones. Once installed, all
combus modules, including motion detectors, can be programmed remotely
via a keypad or the WinLoad upload/download software.
DigiplexNE also supports 32 virtual zones in addition to its 96 security
zones and 32 access control doors. Virtual zones can be used to automate
PGM activations without occupying a security zone and without affecting
the system’s security functions. DigiplexNE is a logical solution to every
installer’s security, access control and home automation installation needs.
CTR-21 APPROVAL
The DigiplexNE control panel (DGP-NE96) meets the European Union
Common Technical Requirement CTR-21. The CTR-21 requirement is an
electrical standard that defines the analogue interface for all two-wire
telecommunications equipment (i.e. DECT, PABXs, etc.) intended for
connection to the Public Switched Telephone Network. This allows the
DigiplexNE control panel to be used in as many as 19 countries, such as
Belgium, Germany, Greece, Portugal, Sweden and Switzerland.
DigiplexNE control panels with the CTR-21 approval are available as an
option only.
1.1 FEATURES
Digital combus:
Provides constant power, supervision and two-way communication
between the control panel and all its modules
Supports up to 127 modules
Connect modules up to 3000ft (914m) from the panel
Sabotage-proof technology without additional wiring
96 addressable zones
8 partitions
998 user codes, 1 System Master code and 1 installer code
Built-in access control
2048 stored events
1 telephone line and optional secondary telephone line
Remote diagnostics and pager messaging
False alarm prevention features
32 independent keyswitch zones (does not use any of the 96 zones)
8 on-board hardwired input terminals
3 on-board fully programmable outputs (PGMs):
1 normally open, high-current transistor output (100mA)
2 normally open or normally closed 5A programmable relay outputs
Up to 32 more PGM inputs through the Keyswitch’s PGM Input
feature
PGM1 can be set as a two-wire smoke detector input
Event reporting:
a separate dialing sequence for each partition
4 Monitoring Station Telephone Numbers
SIA, Contact ID, Ademco Contact ID Edition 2000, Pager Format
and many more communicator formats
1.2 SPECIFICATIONS
CONTROL PANEL (NON-UL SYSTEMS)
AC Power: 16Vac, 20/40VA, 50-60Hz
Battery: 12Vdc, 4Ah minimum
Auxiliary Power: 12Vdc 600mA typical, 700mA maximum,
fuseless shutdown at 1.1A
Bell Output: 1A, fuseless shutdown @ 3A
PGM Output: PGM1 (100mA), PGM2 and PGM3 (5A relay)
Event Buffer: 2048 events
All control panel outputs are rated to operate between 10.8Vdc and
12.1Vdc
CONTROL PANEL (UL COMPLIANT SYSTEMS)
AC Power: 16Vac, 40VA, 60Hz
Battery: 12Vdc, 4Ah minimum
Auxiliary Power: 11.4 to 12.5Vdc, 200mA maximum, fuseless
shutdown at 1.1A
Bell Output: 11.4 to 12.5Vdc, 1A maximum, fuseless
shutdown @ 3A
PGM Output: PGM1 (100mA), PGM2 and PGM3 (5A relay)
Event Buffer: 2048 events
All control panel outputs are rated to operate between 11.4Vdc and
12.5Vdc
Specifications may change without prior notice.
UL Note: The DGP-NE96 control panel has been tested with the LCD Keypad
(DGP2-641) only.
General Note 1
Please note that only LCD and Grafica keypads can be used to program the
DigiplexNE system. LED keypads cannot be used to program the system.
General Note 2
Please note that the steps may differ when programming with the Grafica
keypad (DNE-K07). If not indicated, refer to the complete Grafica User
Manual, which can be downloaded for free from our Web site at
www.paradox.ca.