18 REFERENCE & INSTALLATION MANUAL
6 ARMING AND DISARMING OPTIONS
6.1 ARMING FOLLOWS PARTITION
(Default = disabled) A partition can be set to follow the arming and
disarming status of one or more partitions. If a partition is set to follow more
than one partition, the partition will arm when all the selected partitions are
armed. However, the partition will disarm as soon as one of the selected
partitions is disarmed.
For example, if options [2] and [3] are ON in section [3121], Partition 1 will
automatically arm whenever partitions 2 and 3 are armed. Partition 1 will
disarm when either partition 2 or partition 3 is disarmed.
6.2 RESTRICT ARMING ON SUPERVISION LOSS
S
ECTION [3034]: OPTION [4]
(Default = disabled) When option [4] is enabled, the control panel can
restrict arming if it receives a supervision loss signal from the Omnia
433MHz Wireless System OMN-RCV3 (see section 7.3). Partitions will not
arm until all supervision loss trouble conditions are corrected.
6.3 RESTRICT ARMING ON TAMPER
SECTION [3034]: OPTION [8]
(Default = disabled) When option [8] is enabled, the control panel prevents
arming if it detects a tamper on a zone or module (see section 7.5).
Partitions will not arm until the Installer Code is entered and tamper trouble
conditions are corrected.
6.4 RESTRICT ARMING ON AC FAILURE
S
ECTION [3035]: OPTION [1]
(Default = disabled) When option [1] is enabled, the control panel can
prevent arming if it detects a loss of AC power. Partitions will not arm until
power is restored.
6.5 RESTRICT ARMING ON BATTERY FAILURE
S
ECTION [3035]: OPTION [2]
(Default = disabled) When option [2] is enabled, the control panel prevents
arming if it detects a battery loss or if the battery voltage is less than 10.5V.
The control panel will not arm a partition until all battery trouble conditions
are corrected.
6.6 RESTRICT ARMING ON BELL OR AUXILIARY FAILURE
S
ECTION [3035]: OPTION [3]
(Default = disabled) When option [3] is enabled, the control panel can
prevent arming if it detects that:
the bell or siren is disconnected
the Bell Output has exceeded its current limits
the Auxiliary Outputs have exceeded their current limits
The control panel will not arm any partition until all bell or auxiliary trouble
conditions are corrected.
6.7 RESTRICT ARMING ON TLM FAILURE
S
ECTION [3035]: OPTION [4]
(Default = disabled) When option [4] is enabled, the control panel can
prevent arming if it is unable to access the telephone line. The control panel
will not arm any partition until all TLM trouble conditions are corrected.
6.8 RESTRICT ARMING ON MODULE TROUBLES
S
ECTION [3035]: OPTION [5]
(Default = disabled) When option [5] is enabled, the control panel will
monitor the same Restrict Arming options selected for the control panel
(battery, tamper, supervision, AC, bell, auxiliary and/or TLM failures) for the
modules connected to the combus. The control panel will prevent arming if
the control panel detects the equivalent trouble condition occurring on a
module.
For example, if options [1], [2] and [5] are ON in section [3035], the control
panel prevents arming if it detects an AC or battery failure on the control
panel or on a module connected to the combus.
6.9 TIMED AUTO-ARMING
(Default = disabled) When this option is enabled, the control panel arms the
selected partition every day at the time set by the Auto-Arm Timer (see
section 6.9.1). A 60-second Exit Delay triggers before the partition arms,
but Auto-Arming can be cancelled by entering a valid access code. The
Auto-Arming Option sets the arming method (see section 6.11). If zones are
open when a partition is Auto-Armed, the control panel arms the partition
and considers all open zones as temporarily bypassed (except 24hr.
zones).
When the partition Auto-Arms, the control panel transmits the Auto-Arming
report code programmed in section [3910]. Whether the partition was
successfully armed or not, the control panel will always transmit the Late to
Close report code programmed in section [3912]. Enable option [1] in the
desired section:
Partition 1: [3121]
Partition 1 arms & disarms with:
Option [1] = N/A
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = Partition 8
Partition 5: [3521]
Partition 5 arms & disarms with:
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = N/A
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = Partition 8
Partition 2: [3221]
Partition 2 arms & disarms with:
Option [1] = Partition 1
Option [2] = N/A
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = Partition 8
Partition 6: [3621]
Partition 6 arms & disarms with:
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = N/A
Option [7] = Partition 7
Option [8] = Partition 8
Partition 3: [3321]
Partition 3 arms & disarms with:
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = N/A
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = Partition 8
Partition 7: [3721]
Partition 7 arms & disarms with:
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = N/A
Option [8] = Partition 8
Partition 4: [3421]
Partition 4 arms & disarms with:
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = N/A
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = Partition 8
Partition 8: [3821]
Partition 8 arms & disarms with:
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = N/A
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]