SEKURE DGP2-648 Manuel d'installation Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
20 REFERENCE & INSTALLATION MANUAL
Figure 6-1: Example of Exit Delay Termination
Enable option [4] in the desired section:
6.16.2 No Exit Delay on Remote Arm
(Default = enabled) When a user arms by using a remote control from the
Omnia Wireless System (OMN-RCV3), the control panel will cancel the Exit
Delay and immediately arm the partition. Enable option [8] in the desired
section:
6.17 KEYPAD LOCK-OUT FEATURE
(Default = 000) If a consecutive number of invalid codes are entered into a
keypad, the control panel can be set to lockout access from all the keypads
in the partition for a specified period. Program the number of consecutive
invalid codes from 001 to 255 (000 = disabled) into the desired section:
(Default = 000) Program the duration of the keypad lockout from 001 to 255
minutes into the desired section. Programming 000 into these sections will
not lockout the keypad, the control panel will transmit the Keypad Lockout
report code programmed in section [3937].
6.18 BELL SQUAWK
The control panel can activate the bell output briefly causing the bell or
siren to squawk to alert users that a partition is being armed, disarmed or
that an Entry or Exit Delay was triggered. Enable or disable the desired
option (off = disabled):
6.19 RING-BACK
After disarming the system, the control panel can warn the user that there
was an alarm and that it may be dangerous to enter by having the keypad
beep 10 times and/or by squawking the bell 10 times. The user should
leave immediately and contact the Monitoring Station from a secure
location. Select the section that corresponds to the desired partition and
enable or disable the desired option (off = disabled):
6.20 MAXIMUM BYPASS ENTRIES
(Default = 000) The Maximum Bypass Entries feature limits the number of
zones that can be bypassed in each partition.
For example, program section [3115] with 010. When in Bypass
Programming (see section 15.7), the control panel will not let the user
bypass more than 10 zones in partition 1.
Enter any value between 001 and 096 (000 = no limit).
6.21 DISPLAY “BYPASS” IF ARMED
S
ECTION [3033]: OPTION [5]
(Default = enabled) When option [5] is enabled, the keypads will not display
that zones have been bypassed while the system is armed.
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]
Partition 1: [3125] Partition 3: [3325] Partition 5: [3525] Partition 7: [3725]
Partition 2: [3225] Partition 4: [3425] Partition 6: [3625] Partition 8: [3825]
Partition 1: [3105] Partition 3: [3305] Partition 5: [3505] Partition 7: [3705]
Partition 2: [3205] Partition 4: [3405] Partition 6: [3605] Partition 8: [3805]
Partition 1: [3106] Partition 3: [3306] Partition 5: [3506] Partition 7: [3706]
Partition 2: [3206] Partition 4: [3406] Partition 6: [3606] Partition 8: [3806]
Partition 1: [3124] Partition 3: [3324] Partition 5: [3524] Partition 7: [3724]
Partition 2: [3224] Partition 4: [3424] Partition 6: [3624] Partition 8: [3824]
Option Bell Squawk on: Description
[1] Disarming
Emits 2 squawks upon disarming
(default = disabled).
[2] Arming
Emits 1 squawk upon arming
(default = disabled).
[3] Auto-Arming
Emits 1 squawk every second for 60
seconds before Auto-Arming a partition.
Emits a series of 3 squawks every second
for 10 seconds before arming
(default = disabled).
[4] Exit Delay
Emits 1 squawk every second during the Exit
Delay. Emits a series of 3 squawks every
second during the final 10 seconds of the
Exit Delay (default = disabled).
[5] Entry Delay
Emits 1 squawk every second during the
Entry Delay (default = disabled).
[6]
Remote Arming/
Disarming
Emits 1 squawk upon arming and 2 squawks
upon disarming with a remote control (using
the Omnia Wireless System, OMN-RCV3
(default = enabled) .
Partition 1: [3124] Partition 3: [3324] Partition 5: [3524] Partition 7: [3724]
Partition 2: [3224] Partition 4: [3424] Partition 6: [3624] Partition 8: [3824]
Option Bell Squawk on: Description
[7] Bell Ring-back
Bell or siren emits 10 squawks
(default = disabled)
[8] Keypad Ring-back
Keypad emits 10 beeps
(default = enabled)
Partition 1: [3115] Partition 3: [3315] Partition 5: [3515] Partition 7: [3715]
Partition 2: [3215] Partition 4: [3415] Partition 6: [3615] Partition 8: [3815]
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 63 64

Commentaires sur ces manuels

Pas de commentaire