14 REFERENCE & INSTALLATION MANUAL
4.3.10 24Hr Water Zones*
SECTIONS [0101] TO [0196]: FIRST DIGIT = A
When a 24Hr Water zone opens, whether it is armed or disarmed, the
control panel will immediately generate an alarm. The SIA FSK reporting
format includes specific codes to identify the alarm as a Water Alarm.
4.3.11 24Hr Freeze Zones*
SECTIONS [0101] TO [0196]: FIRST DIGIT = B
When a 24Hr Freeze zone opens, whether it is armed or disarmed, the
control panel will immediately generate an alarm. The SIA FSK reporting
format includes specific codes to identify the alarm as a Freeze Alarm.
* UL Note: UL Listed compatible devices shall be used for UL systems. For
UL Listed systems, this type of zone shall be programmed as a silent auxiliary
alarm.
4.3.12 Delayed 24Hr Fire Zone (Not to be used with UL Listed systems)
SECTIONS [0101] TO [0196]: FIRST DIGIT = C
The Delayed 24Hr Fire Zone definition from Figure 4-3: on page 14 is
commonly used in residential homes where a smoke detector often
generates false alarms (i.e. cigarette smoke, burning bread, etc.). A zone
programmed as Fire becomes normally open (will not function as normally
closed) and requires an EOL resistor.
The keypads must be assigned to the same partition as the
Delayed 24Hr Fire zone for the buzzer to activate.
Figure 4-3: Delayed 24Hr Fire Zone
4.3.13 Standard 24Hr Fire Zone
SECTIONS [0101] TO [0196]: FIRST DIGIT = D
A zone programmed as Fire becomes normally open (will not function as
normally closed) and requires an EOL resistor.
When a Standard 24Hr Fire Zone triggers, the control panel can:
send a Zone Alarm report code (see section 8.2.1 on page 24).
send a Fire Loop Trouble Report (see section 8.2.11 on page 25) if a
tamper/wiring fault occurs on a Fire Zone. A “Zone Fault Trouble” will
also appear in the keypad's Trouble Display.
generate a Fire alarm, which is always audible, regardless of other
settings. Fire alarms generate an intermittent signal (see Figure 4-4).
Figure 4-4: Bell/Siren Output During Fire Alarm
4.3.14 Stay Delay Zone
SECTIONS [0101] TO [0196]: FIRST DIGIT = E AND F
When a Stay Delay zone is armed using the Regular or Force arming
methods, the control panel processes the zone as an Instant zone (see
section 4.3.4). When a Stay Delay zone is armed using the Stay or Instant
arming methods and the zone is triggered, the control panel will not
generate an alarm until the programmed Stay Delay elapses. A zone
defined as Stay Delay 1 follows the Entry Delay 1 Timer of its assigned
partition. Likewise, a zone defined as Stay Delay 2 follows the Entry Delay
2 Timer of its assigned partition. To program the Entry Delay Timers, refer
to Entry Delays 1 and 2 on page 13.
For example, if zone 1 in Partition 5 is defined as Stay Delay 1, the timer
will follow the amount programmed in [3511].
4.4 ZONE PARTITION ASSIGNMENT
S
ECTIONS [0101] TO [0196]: SECOND DIGIT = 1 TO 8
A control panel can be divided into eight completely independent systems
(see section 11.9 on page 32). Assign each zone to one partition (see
Figure 4-1 on page 12).
4.5 ZONE OPTIONS
The zone options from Figure 4-1 on page 12 are described below.
4.5.1 Auto Zone Shutdown
SECTIONS [0101] TO [0196]: OPTION [1]
(Default = 000) When option [1] is disabled, the control panel generates an
alarm when an armed zone is breached even if the same zone opens
repeatedly during the same alarm, which may cause several reportings and
further activation of the bell output. When option [1] is enabled, the control
panel will stop regenerating alarms on the zone during the same armed
period once the Auto Zone Shutdown Limit is reached. The Auto Zone
Shutdown Limit resets every time the system is armed. To program the
Auto Zone Shutdown Limit, key in the desired 3-digit counter (000 to 255)
into section corresponding to the desired partition (000 = disabled):
4.5.2 Bypass Zones
SECTIONS [0101] TO [0196]: OPTION [2]
Only zones with option [2] enabled can be Manually Bypassed (see section
15.7). Fire Zones cannot be bypassed. Default = enabled.
Delayed Fire Zone
Triggered
Activate bell/siren output & delay
report transmission for 30 seconds.
Yes
Yes
Any key on
keypad pressed
within 30
seconds?
Bell/siren silenced. Delay report
transmission an additional 90 sec.
Problem
corrected?
Latch alarm and transmit
report code as described
in the section "Standard
24Hr. Fire Zone".
END
Alarm Disabled
No
Has a 2nd
Delayed Fire
Zone opened in
30 sec.?
No
Yes
Yes
No
Has the zone
closed within
30 seconds?
Yes
No
Partition 1: [3114] Partition 5: [3514]
Partition 2: [3214] Partition 6: [3614]
Partition 3: [3314] Partition 7: [3714]
Partition 4: [3414] Partition 8: [3814]