Page 1 - User Manual

642 LCD KeypadUser Manual

Page 2

8 User Manual3.0 Access CodesAccess codes are personal identification numbers that allowyou to enter certain programming modes and arm or disarmthe sy

Page 3 - TABLE OF CONTENTS

Esprit+ 642 LCD Keypad 93.3 Programming Access CodesThe display will read: none to indicate that anaccess code is available (does not containinformati

Page 4 - 2 User Manual

10 User Manual3.4 Deleting an Access CodeHow Do I Delete an Access Code?1) Press the [ENTER] key. The display will briefly read: enter code to program

Page 5 - 1.0 Introduction

Esprit+ 642 LCD Keypad 114.0 Arming & DisarmingFor information on how to arm and disarm a partitionedsystem, please see “Partitioning the System”

Page 6 - = to indicate a tip

12 User ManualPressing the [CLEAR] key will only erase the displaymessage and will not erase the memory contents.Arm or disarm to erase the memory con

Page 7 - 2.0 Basic Operation

Esprit+ 642 LCD Keypad 134.5 Stay ArmingStay arming allows you to remain in the protected area whilepartially arming the system. You may choose to hav

Page 8 - 2.3 Auditory Feedback

14 User Manual4.6 Fast ExitThis feature allows you to leave a perimeter that is alreadyarmed in Stay mode and have the system rearm itself. Youcan set

Page 9 - 2.4 Info List

Esprit+ 642 LCD Keypad 154.8 Force ArmingForce arming enables you to rapidly arm the system withoutwaiting for all the zones in the system to close. F

Page 10 - 3.0 Access Codes

16 User Manual4.9 Manual Bypass ArmingThis feature allows you to deactivate (ignore) specified zonesthe next time you arm the system. Once armed and t

Page 11 - 3.3 Programming Access Codes

Esprit+ 642 LCD Keypad 174.11 One-Touch ArmingOne-Touch arming allows you to arm the system using asingle key without using an access code. These feat

Page 13 - 4.0 Arming & Disarming

18 User Manual4.11.2 One-Touch Stay ArmingRefer to “Stay Arming” on page 13 for a full explanation of thisfeature.4.12 Keyswitch/Push-Button ArmingYou

Page 14 - 4.4 Regular System Arming

Esprit+ 642 LCD Keypad 194.14 No Movement Automatic ArmingYour installer can program your panel to send a report and/orarm the system if the system is

Page 15 - 4.5 Stay Arming

20 User Manualmode. To silence/reset a fire alarm, enter a valid accesscode. In case of fire follow your evacuation plan. If there is nofire condition

Page 16 - 4.6 Fast Exit

Esprit+ 642 LCD Keypad 21succumbing to its hazardous effects. This may occur withintwo or three minutes upon detection of a fire. Advancewarning of a

Page 17 - 4.8 Force Arming

22 User Manual5.0 Additional FeaturesSeveral keypad features can be programmed directly by you,without the help of an installer.5.1 Chime Zone Selecti

Page 18 - 4.10 Bypass Recall

Esprit+ 642 LCD Keypad 23 5.3 Panic AlarmsIf you wish to signal a panic situation, your installer canprogram three panic zones on your keypad. You may

Page 19 - 4.11 One-Touch Arming

24 User Manual5.4 Setting Time and DayHow Do I Use Panic Alarms?Press and hold both the [1] and [3] keys to generate apanic signal. The display will r

Page 20 - 4.13 Timed Auto-Arming

Esprit+ 642 LCD Keypad 255.5 Quick Function KeysSeveral control panel features can be programmed quickly onthe keypad. The Security Company or install

Page 21 - 4.15 Fire Alarms

26 User Manual5.6 Keypad SettingsYou can modify the keypad settings to suit your needs.[FORCE]Answer PC. The display will read: answer PC.This will in

Page 22 - 20 User Manual

Esprit+ 642 LCD Keypad 275.7 Event ListYour control panel will create a buffer which contains a recordof all system activities including the time and

Page 23 - Esprit+ 642 LCD Keypad 21

Esprit+ 642 LCD Keypad 1TABLE OF CONTENTSIntroduction ...3Legend ...

Page 24 - 5.0 Additional Features

28 User Manualoccurred and what event occurred will scroll on the screen.As you press the [V] key, the next pair will scroll onto thescreen.Figure 5.1

Page 25 - 5.3 Panic Alarms

Esprit+ 642 LCD Keypad 295.8.1 Arming a Partitioned SystemZones can be divided into two systems. Based on yourrequirements, the installer designates w

Page 26 - 5.4 Setting Time and Day

30 User ManualIf your Access Code has access to System B:5.9 Disarming System A and B SeparatelyHow Do I Arm System A?1) Press the [STAY] key.2) Enter

Page 27 - 5.5 Quick Function Keys

Esprit+ 642 LCD Keypad 31If your Access Code has access to System A:If your Access Code has access to System B:5.10 Testing & MaintenanceWe recomm

Page 28 - 5.6 Keypad Settings

32 User ManualYour installer can advise you of the best way to test yourparticular system.5.10.1 Fire Alarm TestingDo not use flame or any kind of bur

Page 29 - 5.7 Event List

Esprit+ 642 LCD Keypad 336.0 Trouble DisplayThe screen can display several trouble conditions. Whentrouble conditions occur, the display reads: system

Page 30 - 5.8 Partitioning the System

34 User ManualPower FailureIf AC power is not being supplied to the control panel and/orthe power supply is unable to charge the battery. The LCDdispl

Page 31 - Esprit+ 642 LCD Keypad 29

Esprit+ 642 LCD Keypad 357.0 System Check list7.1 Panic Buttons7.2 Zone ChecklistIs this a partitioned system? Yes NNo NSystem A =____________Syst

Page 32 - How Do I Arm System B?

36 User ManualEntry Delay 1 is ________seconds.Entry Delay 2 is ________seconds.Exit Delay is ___________seconds.Zone # and DescriptionSystemA BZone

Page 33 - How Do I Disarm System B?

Esprit+ 642 LCD Keypad 377.3 User Access Code ListUser Name System User Name System01: 16:02: 17:03: 18:04: 19:05: 20:06: 21:07: 22:08: 23:09: 24:10:

Page 34 - How Do I Test the System?

2 User ManualOne-Touch Arming ...17Keyswitch/Push-Button Arming ...

Page 35 - Trouble List

38 User ManualFor security reasons, write only user names, and notactual access codes.Other informationThis alarm system was installed on:____________

Page 36 - 34 User Manual

Esprit+ 642 LCD Keypad 39WarrantyParadox Security Systems Ltd. (“Seller”) warrants its products to be free fromdefects in materials and workmanship un

Page 37 - 7.0 System Check list

Notes_________________________________________________________________________________________________________________________________________________

Page 39 - 7.3 User Access Code List

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CanadaTel.: (450) 491-7444 Fax: (450) 491-2313www.paradox.ca

Page 40 - Other information

Esprit+ 642 LCD Keypad 31.0 IntroductionThank you for selecting the Esprit+ Security System fromParadox Security Systems. The Esprit+ line of security

Page 41 - Warranty

4 User Manual= to indicate a tip.= to indicate a button on the keypad.[KEY]

Page 42

Esprit+ 642 LCD Keypad 52.0 Basic OperationMany of the features in your system must be enabled by yourinstaller. If the feature is not programmed, the

Page 43

6 User ManualWhen zone status is normal, the LCD display will read:system ready. If any zones are open, the display willread: zones open. While the di

Page 44

Esprit+ 642 LCD Keypad 7the system switches to a new status/mode, the keypadsounder will produce an intermittent beep tone (four shortbeeps).• Rejecti