Vue de la page 113
104
Silencing Trouble Beeps
Pressing the STATUS button on a touchpad, pressing # + * from any
phone, or changing the arming level while the system has a trouble
condition stops trouble beeps and voice messages. Trouble beeps be-
gin again 10 hours later unless the trouble condition is resolved.
Troubleshooting Problems
This section contains a summary of system troubleshooting tech-
niques.
2-STAY System is armed to lev-
el 2.
System is armed to level 2,
and a door or window sen-
sor has been bypassed or
something is wrong, such
as a low battery or sensor
failure.
3-AWAY System is armed to lev-
el 3.
System is armed to level 3,
and a door or window sen-
sor has been bypassed or
something is wrong, such
as a low battery or sensor
failure.
*
Not all touchpads have a display available.
The most common reason a display number flashes is that security pro-
tection has been turned on with a door or window open (sensor bypass).