Spectra LED Keypads 11
power supply against current overload and automatically shuts
down if the current exceeds 1.1A. If this occurs, the [6] button
will illuminate.
2.5.7 Communication Failure [7]
If your alarm system is monitored and it could not communicate
with the Security Company, the [7] button will illuminate.
2.5.8 Timer Loss [8]
When the [8] button illuminates, your alarm system’s clock
must be re-programmed. This is the only trouble that we
recommend that you correct.
2.5.9 Tamper/Zone Wiring Failure [9]
When the [9] button illuminates, a wiring problem is occurring
on one or more zones.
2.5.10 Telephone Line Monitoring Failure [10]
When the [10] button illuminates, the system has not detected
the presence of a telephone line for more than 30 seconds.
To re-program the clock press the [8] button after Step 2 from
the Trouble Display (see “How Do I Access the Trouble
Display?” at the beginning of section 2.3) and enter the current
time using the 24-hour clock (i.e. 8:30PM = 20:30). Also, refer
to section 5.4 and Appendix A.
To view which zones are experiencing trouble, press the [9]
button after Step 2 from the Trouble Display (see “How Do I
Access the Trouble Display?” at the beginning of section 2.3)
(see Zone Display: section 2.3).