MONITOR PLACEMENT
The UltraGuard Monitor may be placed on any wall that provides convenient access to the furnace emergency shut off switch
wiring. For ease of use the UltraGuard Monitor should be placed at or near eye level.
Locations to Avoid:
As with any electronic device, the following locations should be avoided:
· Within 5 feet of any cooking appliance.
· Near open windows or doors.
· Near a bathroom where the moist air from the shower could result in the UltraGuard becoming repeatedly wet.
· Very cold or very hot environments where the ambient temperature can exceed the recommended operating range of
the unit 32°F to 120°F (0°C to 50°C).
The UltraGuard Monitor should not be located on an outside wall where severe cold weather could cause a false low temperature
alarm.
NOTE: The use of a battery backup power supply, as indicated in the "Alternate Power Source" section, will help to prevent
momentary furnace interruptions and alarm trouble indications.
WARNING: Always turn the furnace circuit breaker off before installing or servicing an UltraGuard system. Before
proceeding, verify that the power has been disconnected from the furnace and the furnace emergency shut off switch.
Zone Relay Outputs should only be connected to power limited circuits. Please note that CO Detector circuits are power limited,
and furnace wiring is not power limited.
DETECTORS PLACEMENT
One of the most important considerations in any CO alarm system is the location of the Detectors. Statistics of the National
Fire Protection Association (NFPA) show that most of the fatal CO occurrences happen at night while people are sleeping. Early
warning of CO is best achieved by the correct installation of CO Detectors. Placement of a Detector in a garage may cause an
alarm due to CO from automotive exhaust.
RECOMMENDED MOUNTING LOCATIONS
Put a CO Detector inside each bedroom where the occupant closes the door while sleeping. A closed door can block particulate
smoke, but CO gas is likely to get through. Please conform to local building codes and regulations.
NOTE: Carbon Monoxide is lighter than air and, therefore, rises.
CO Detector must be mounted on the wall or ceiling more than 5 feet above the floor.
WALL LOCATION: Locate the top of the CO Detector 5 feet and above from the
floor (figure 8).
CEILING LOCATION: CO Detector should be mounted as close as possible to
the center of a hallway or room. If this is not possible, the edge of the CO Detector
should be at least 4 inches from any wall.
Good ventilation is recommended when household cleaning supplies or similar
contaminants are stored or frequently used.
Figure 6. Recommended CO Detectors And Monitor
Placement For Multi-Level Residence
Figure 7. Recommended CO Detector Placement
For Single Floor Residence
Figure 8. CO Detector Wall Placement